bmKan

Open Cooling Tower ye mun ye?

Dec 19, 2025

Aw bɛ cikan bila .

 
 

Open Cooling Tower ye mun ye?

Nɛnɛbɔlan dafalenw ye da wulilenw-circuit nɛnɛminɛnw ye minnu bɛ kɛ kosɛbɛ izini ni siwili nɛnɛbɔlanw na. U ka sariyakolo jɔnjɔn ye ka ji lamininenw funteni dɔgɔya ka tɛmɛfiɲɛ ni ji cɛsira tilennenni funteni bɔli ye min bɛ kɛ ni fɛn ye min bɛ wele ko evaporative heat dissipation ani convective heat transfer. U bɛ dɔn ni jɔcogo nɔgɔman ye, nɛnɛ nafa ka bon ani musaka dɔgɔman, u bɛ baara kɛ kosɛbɛ kemikɛli, fanga, cɛmancɛ fiɲɛdilan, nɛgɛso ani izini wɛrɛw nɛnɛ siraw la.

 
1396

tɔndenw minnu bɛ baara kɛ

 
15+

san caman dɔnniya

 
125+

ko kɛlenw & gɛlɛyaw

 
12

kalanfa dɔnbagaw

 

 

Jagokɛcogo siratigɛ la, nɛnɛbɔlanw dabɔlenw bɛ kɛ kɛrɛnkɛrɛnnenya la fɛn kolomaw ye i n’a fɔ sankanso farikolo, fasafɛnw, ventilateur, ji tilacogo, sump ani fiɲɛbɔlanw. Baara kɛtuma na, ji lamininen min ka kan ka nɛnɛ, o bɛ lase ji tilayɔrɔ la sankanso sanfɛ ji pɔnpe fɛ, o kɔfɛ, a bɛ fiyɛ cogo kelen na fasafɛn sanfɛla la ni fɛnɲɛnamafagalanw ye walima ji tilayɔrɔw fɛ walasa ka ji filimu finman dɔ kɛ. O waati kelen na, ventilateur min sigilen bɛ sankanso duguma walima a sanfɛ, o bɛ fiɲɛ bila ka don sankanso kɔnɔ fiɲɛbɔyɔrɔw fɛ, o bɛ kɛ sababu ye ka ɲɔgɔn sɔrɔ ni ji filimu ye min bɛ fasa yɔrɔ la. O kɛcogo in na, fan dɔ fɛ, funteni jiginni bɛ Kɛ fiɲɛ ni ji cɛ, ka funteni hakililama yɔrɔ dɔ Lase ji la ka Taa fiɲɛ na; faan wɛrɛ fɛ, ji lamininen yɔrɔ dɔ bɛ funteni minɛ ka wuli, ka funteni dogolen caman bɔ a la. Funteni ɲɔgɔn falen-falen nɔ fila kɔnɔ, ji nɛnɛma bɛ bin sankanso duguma jibɔyɔrɔ la, ka segin ka taa minɛn nɛnɛnenw na walasa ka u lasegin u cogo kɔrɔ la, ka sɔrɔ fiɲɛ funteni ni nɔgɔlen bɛ bɔ fiɲɛ na fiɲɛbɔlan fɛ min bɛ sankanso sanfɛ.

 

Field Application Display Closed-Circuit Cooling Tower in Operation

 

 

Nɛnɛbɔyɔrɔ dafalenw nafa jɔnjɔnw bɛ u ka nɛnɛ nafamaba la-funteni ɲɔgɔn falen-falen tilennen bɛ se ka funteni bɔ teliya la ji lamininen na walasa ka nɛnɛ magoɲɛfɛnw ɲɛ minnu bɛ se ka kɛ ni fanga caman ye. O waati kelen na, u jɔcogo ka nɔgɔn kosɛbɛ, sanni, u sigili ani u ladonni musakaw ka dɔgɔ; baarakɛcogo kɔrɔ-baara kɔfɛ, o bɛ fasafɛnw saniya tuma bɛɛ dɔrɔn de wajibiya, ka fiɲɛbɔlanw sɛgɛsɛgɛ ani k’u dilan, ani ka ji lamininenw falen kokura. Nka, danyɔrɔ jɛlenw fana bɛ o minɛn suguw la: k’a sababu kɛ ji ni fiɲɛ lamininenw ka ɲɔgɔn sɔrɔ tilennen ye, buguri, nɔgɔw, fɛnɲɛnama misɛnninw ani fɛn wɛrɛw minnu bɛ fiɲɛ kɔnɔ, olu bɛ se ka don ji la, o bɛ na ni ji lamini ji cogoya tiɲɛni ye, o min bɛ kɛ sababu ye ka pibilikiw ni funteni sɛnɛfɛnw sɔgɔsɔgɔ ani ka u sɔgɔ.

 

Customer Site Installation of Closed-Circuit Cooling Tower

 

O la, a ka kan ka ji saniyacogo dɔ labɛn ani ka ji saniya furaw fara a kan tuma bɛɛ i n’a fɔ sɔgɔsɔgɔninjɛ balilanw ni banakisɛfagalanw. Ka fara o kan, nɛnɛbɔyɔrɔ dafalenw bɛ ni bɔgɔbɔgɔli bɔnɛ ye, o min bɛ dan sigi u kɛli la ji-yɔrɔw la minnu ka dɔgɔ walima ko minnu bɛ jiko jateminɛ.

 

 

Closed-Circuit Cooling Tower Manufacturing Facility

 

Baarakɛcogo ɲuman na, a ka c’a la, nɛnɛbɔlan dafalenw bɛ tila suguya fila ye ka kɛɲɛ ni fiɲɛbɔcogo ye: crossflow suguya ani counterflow suguya. Crossflow open cooling towers kɔnɔ, fiɲɛ bolicogo sira bɛ tilennen to ji bolicogo la, sankanso farikolo janya dɔgɔyali ni ladonni nɔgɔman bɛ o la. Nɛnɛ da wulilenw na, fiɲɛ bɛ woyo ka taa sira wɛrɛ fɛ ni ji bolicogo ye, o bɛ kɛ sababu ye ka funteni ɲɔgɔn falen-falen bɛrɛbɛrɛ sɔrɔ ani ka nɛnɛ kɛcogo ɲuman sɔrɔ, o la, a bɛnnen don izini ko kɛlenw ma ni wajibi gɛlɛnw ye nɛnɛ nɔ na.

 

Aw ye ɲininkali ci .